{"id":260073,"date":"2024-05-16T17:22:39","date_gmt":"2024-05-16T17:22:39","guid":{"rendered":"https:\/\/sola-diagnostics.com\/?p=260073"},"modified":"2025-01-09T11:58:01","modified_gmt":"2025-01-09T10:58:01","slug":"equivalence-of-different-sampling-methods","status":"publish","type":"post","link":"https:\/\/sola-diagnostics.com\/en\/equivalence-of-different-sampling-methods\/","title":{"rendered":"Equivalence of different sampling methods"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; theme_builder_area=&#8221;post_content&#8221; _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221;][et_pb_row _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; type=&#8221;4_4&#8243; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;]<\/p>\n<h3 id=\"ember652\" class=\"ember-view reader-content-blocks__heading-3\">The study investigated whether different sampling methods influence the validity of the WID\u00ae-easy Test (&#8220;WID-qEC test&#8221; in the scientific literature)<\/h3>\n<p id=\"ember653\" class=\"ember-view reader-content-blocks__paragraph\">Specifically, it compared Cervex brush with PreservCyt against FLOQSwab with eNAT, physician-performed sampling with patient self-sampling, and the exact sampling site (vaginal, cervico-vaginal, or cervical) to assess their influence on the test\u2019s performance.<\/p>\n<p id=\"ember654\" class=\"ember-view reader-content-blocks__paragraph\">The results demonstrated that the test results remained consistent irrespective of the sampling method, even for samples stored at room temperature for seven days. While self-sampling led to high specificity, the sensitivity was somewhat lower.<\/p>\n<p id=\"ember655\" class=\"ember-view reader-content-blocks__paragraph\">Overall, the WID-qEC test offers a simple, objective and non-invasive method for assessing the risk of malignancy in women with abnormal bleeding.<\/p>\n<p id=\"ember656\" class=\"ember-view reader-content-blocks__paragraph\"><strong>The study is available for download <a href=\"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ijc.35000\" target=\"_blank\" rel=\"noopener\" title=\"High performance of the DNA methylation-based WID-qEC test for detecting uterine cancers independent of sampling modalities\">here<\/a>:<span class=\"white-space-pre\"> <\/span><\/strong><\/p>\n<div class=\"reader-image-block reader-image-block--full-width\">\n<figure class=\"reader-image-block__figure\">\n<div class=\"ivm-image-view-model   \">\n<div class=\"ivm-view-attr__img-wrapper\"><\/div>\n<\/div>\n<\/figure>\n<\/div>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; type=&#8221;4_4&#8243; theme_builder_area=&#8221;post_content&#8221;][et_pb_image _builder_version=&#8221;4.22.1&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221; title_text=&#8221;Screenshot 2024-06-03 at 191240&#8243; src=&#8221;https:\/\/sola-diagnostics.com\/wp-content\/uploads\/2024\/06\/Screenshot-2024-06-03-at-191240.png&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243; url=&#8221;https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ijc.35000&#8243; url_new_window=&#8221;on&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The study investigated whether different sampling methods influence the validity of the WID\u00ae-easy Test (&#8220;WID-qEC test&#8221; in the scientific literature)<\/p>\n","protected":false},"author":2,"featured_media":260898,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"1500","footnotes":""},"categories":[14],"tags":[],"class_list":["post-260073","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/posts\/260073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/comments?post=260073"}],"version-history":[{"count":0,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/posts\/260073\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/media\/260898"}],"wp:attachment":[{"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/media?parent=260073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/categories?post=260073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sola-diagnostics.com\/en\/wp-json\/wp\/v2\/tags?post=260073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}